• Standard with 300watt or 400watt PS/2 or 350watt Redundant Power Supply • Front Panel Indicators for Power and HDD Activity • Three 5.25inch Front Accessible Drive Bays • One 3.5inch Front Accessible Drive Bay • Front Panel Controls for Power, Reset • Replaceable, Washable Air Filter • Two 3.5inch Internal Drive Bay • One 120mm Cooling Fan
|
DESCRIPTION:
The RME-4400 is one of the most cost effective 4U Rackmount Computer / Server in our 4U product group. The RME-4400 has a 16ga cold rolled steel case, fronted by a 0.125" thick front panel with locking door to protect access to the power and reset switches and the exposed drive access. This rack server case supports three 5¼" exposed drive bays, one 3½" floppy bay and two 3½" and hidden drives. Both ATX and mATX motherboards are supported as are ISA, PICMG, PISA and PCI only passive backplanes up to 14 aggregate slots, standard form factor AT and ATX power supplies are typical with optional redundant AT or ATX power supplies readily available. Native support for Pentium, Pentium 3, Pentium 4 and XEON systems.
GENERAL SPECIFICATIONS:
DISK DRIVE BAY One 3½inch, three 5¼inch front accessible drive bays and two 3½inch internal drive bays
BACKPLANE 14-slot PICMG, 15-slot PICMG or 14-slot ISA backplane(RME-44 51)
MOTHERBOARD ATX form factor (RME-44 11)
POWER SUPPLIES 300watt, 400watt PS/2 form factor with ball bearing fan, 50,000hours MTBF (including fan) or 350watt mini dual redundant with two ball bearing fans 50,000hours MTBF per module (including fans)
CONTROLS VIA FRONT PANEL Power on/off switch, system reset button, keyboard lock switch behind lockable translucent door
INDICATORS ON FRONT PANEL Power on, HDD activity
KEYBOARD CONNECTOR Pre-Wired 5-pin DIN connector on front panel
USB INTERFACE One USB port on front panel
SPEAKER 8ohm speaker
COOLING Positive pressure cooling fan via one 120mm with replaceable filter in front of chassis
ENVIRONMENTAL
OPERATING TEMPERATURE 0~50°C (32~122°F)
RELATIVE HUMIDITY 10~95% @ 40°C (104°F), non-condensing
ALTITUDE 3000m (10,000feet)
VIBRATION (OPERATING) 5~17Hz, 0.1inch double amplitude, 17~500Hz, 1.5G acceleration peak to peak
SHOCK Operating 2.5G @ 15~20ms (35G @ 15~20ms non-operating)
DIMENSIONS 483mm W x 177mm H x 450mm D (19inch x 7inch x 17.7inch)
WEIGHT Net 12.8kg (28.2lbs) without motherboard or backplane, computer board, drives or power supply
APPEARANCE
CONSTRUCTION Heavy-duty steel chassis
COLOR Beige
CERTIFICATIONS
SAFETY UL / CSA / TÜV / CE/ FCC
EMI FCC / VDE class A
RME-44 51 BACKPLANE OPTIONS
SGB-1222 15-slot PICMG backplane: two PICMG, twelve PCI, two ISA slots (see datasheet and/or website for more information)
SGB-7062 14-slot PICMG backplane: two PICMG, seven PCI, six ISA slots (see datasheet and/or website for more information)
SGB-4092 14-slot PICMG backplane: two PICMG, four PCI, nine ISA slots (see datasheet and/or website for more information)
SIB-0142 14-slot ISA backplane (see datasheet and/or website for more information)
RME-44 11 POWER SUPPLY OPTIONS
43RP 400watt ATX power supply (PS/2 size); Voltage input: 95~264VAC @ 47~63Hz, active power factor correction; Voltage output (max. load): +3.3VDC @ 28A, +5VDC @ 40A, +12VDC @ 15A, -5VDC @ 0.3A, -12VDC @ 0.8A, +5VSB @ 2A
63PP-2 350watt mini dual redundant hot-swappable power supply (4U form factor); Voltage input: 90~264VAC @ 47~63Hz, power factor correction; Voltage output (max. load): +3.3VDC @ 28A, +5VDC @ 33A, +12VDC @ 15A, -5VDC @ 0.3A, -12VDC @ 0.5A +5VSB @ 2A
RME-44 51 POWER SUPPLY OPTIONS
43LP 300watt ATX power supply (PS/2 size); Voltage input: 90~264VAC @ 47~63Hz, active power factor correction; Voltage output (max. load): +3.3VDC @ 28A, +5VDC @ 30A, +12VDC @ 15A, -5VDC @ 0.3A, -12VDC @ 0.8A, +5VSB @ 2A
43RP 400watt ATX power supply (PS/2 size); Voltage input: 95~264VAC @ 47~63Hz, active power factor correction; Voltage output (max. load): +3.3VDC @ 28A, +5VDC @ 40A, +12VDC @ 15A, -5VDC @ 0.3A, -12VDC @ 0.8A, +5VSB @ 2A
63PP-2 350watt mini dual redundant hot-swappable power supply (4U form factor); Voltage input: 90~264VAC @ 47~63Hz, power factor correction; Voltage output (max. load): +3.3VDC @ 28A, +5VDC @ 33A, +12VDC @ 15A, -5VDC @ 0.3A, -12VDC @ 0.5A +5VSB @ 2A
|
|